Belt unit

Service life of the belt unit

The rough guide of replacing the belt unit is around 80,000 pages of simplex printing in landscape on A4-sized paper (3 pages at a time).


To check the life of the belt unit, select [Configuration] - [Supplies Status] - [Belt] from the operator panel.


Replacement cycle of the belt unit

When the time for replacement is approaching or has arrived, the following message appears on the display.


When the time for replacement is approaching
→
When the time for replacement has arrived
Displayed message

Belt Unit Near Life.

→

Install New Belt Unit.

Response to the message
Please prepare a new belt unit.
→
Please replace the belt unit with a new one.
State of this machine
Printing is possible, but the belt unit is approaching the end of its service life.
→
The belt unit has reached the end of its service life. Printing stops.

About 2,000 pages can be printed from when the time for replacement is approaching to when the time for replacement has arrived.


  • The actual printable pages before replacing the belt unit varies with the usage conditions.
  • A message indicating replacement of the belt unit may be displayed without displaying a message indicating that the time for replacement is approaching.
    In this case, please replace the belt unit.
  • Replace the belt unit immediately when a message indicating replacement of the belt unit is displayed and printing has stopped.
    If you repeatedly open and close the front cover so that you can continue printing temporarily, a failure may be caused or the print quality may be degraded.
    In addition, after a certain period of time, printing will be disabled even if you open and close the front cover. (The printable period of time varies with the usage condition.)
  • If [Admin Setup] - [Panel Setup] - [Near Life Status] is set to [Disable], a message indicating the time for replacement will not be displayed.
  • Handle with adequate care since (the green tube of) the image drum is very easy to be damaged.
  • Do not expose the image drum to direct sunlight or strong light (approx. 1,500 lux or above). Do not leave it uncovered for more than 5 minutes even under room lighting.

  • You can change the timing for displaying a message indicating the time for replacement of the belt unit. The factory default value is [2000].
    This timing is set from [Admin Setup] - [Others Setup] - [Near Life Setup] - [Belt Near Life Timing] on the operator panel.