Cleaning the LED Head
Clean the LED head if vertical white lines appear, images are faded, or the periphery of letters are smudged in the printouts.
Note
-
Do not use solvents, such as methyl alcohol or thinners, because they may damage the LED head.
-
Do not expose the image drum to direct sunlight or strong light (approximately 1,500 lux or more). Even under room lighting, do not leave the image drum for 5 minutes or more.
-
Hold the handle (A) to open the scanner unit.
-
Insert your finger into the recess (B) on the right side of the machine and pull the front cover open lever (1) to open the front cover (2) forward.
-
Press the button (C) and open the Output Tray (3).
Burns may result.
The fuser unit is extremely hot. Do not touch it.
-
Wipe the four lenses of the LED heads with a soft tissue paper lightly.
-
Close the Output Tray by pushing the both sides of the Output Tray firmly.
-
Close the front cover.
Note
The front cover cannot be closed if the Output Tray is not closed securely.
-
Hold the handle (A) to close the scanner unit.