Manage Unit

Operation Clear

Item

Factory default setting

Description

Operation Timeout

3

Sets time for automatic reset of screen to begin.

Available range: 1 to 10 minutes

Clear After Job

OFF

Sets whether to reset after job is completed.

Sound Control

Item

Factory default setting

Description

Paper Jam Error Buzzer Volume

Middle

Sets the volume for the paper jam alert tone.

AirPrint Buzzer Volume

Low

Sets the AirPrint confirmation operation sound.

Local Interface*1

Item

Factory default setting

Description

USB Menu

USB

Enable

Sets whether to enable USB.

Soft Reset

Disable

Sets whether to enable the soft reset command.

Speed

480Mpbs

Selects the maximum transfer speed of USB interface.

Offline Receive

Disable

Set whether to receive data in offline state or in recoverable error state.

Serial Number

Enable

Sets whether to use a USB serial number.

Connected Host

Normal

Sets a host to be connected.

System Setup

Item

Factory default setting

Description

Access Control

Disable

Sets access control.

Default Authentication Method Setting

Local Name

Available only when [Access Control] is set to [Enable].

Unit of Measure

Millimeter or Inch

Selects a displayed unit (millimeter / inch).

Default Paper Size

A4 or Letter

Sets the default paper size.

Date Format

dd/mm/yyyy or mm/dd/yyyy

Sets the date format.

Allow All Reports To Print

Disable

Sets whether to allow printing reports with personal information.

Near Life LED

Enable

Sets whether to light an LED if a near life warning occurs.

Near Life Status

Enable

Sets whether to display a message if a near life warning occurs.

Status Display

Toner Gauge

Specify display information in idle Display.

Paper Size: Display paper size of each tray.

Toner Gauge: Display toner gauge.

Panel Contrast

0

Sets the contrast of the display screen.

USB Memory Interface

Enable

If [Disable] is set, the print from USB Memory function cannot be used.

Power Save

Item

Factory default setting

Description

Power Save Time

1 minute

Sets when to enter Power Save mode.

Sleep Time

15 minutes

Sets when to enter Sleep mode.

Auto Power Off Time

4 hours

Sets when to enter Auto Power Off.

Silent Mode

ON

Specifies a print preparation operation when entering standby status from Sleep mode.

If [ON] is set: it is quiet as there is no print preparation.

If [OFF] is set: there is a rotation noise of the image to perform print preparation but you can start first printing early.

ECO Mode*1

ON

If [ON] is set: Printing starts even before the temperature of the fuser reaches the prescribed degrees, if the job is small.

If [OFF] is set: Printing starts after the temperature of the fuser reaches the prescribed degrees.

Memory Setup

Item

Factory default setting

Description

Receive Buffer Size

Auto

Sets the reception buffer size that local interface secures.

Resource Save

OFF

Sets the resource save area.

Flash Memory Setup*1

Item

Factory default setting

Description

Initialize

Execute

Initializes a flash memory.

This item is displayed when [Initial Lock] is set to [Disable].

Format Partition

PCL

(NULL)

Formats a partition.

Common

(NULL)

PS

(NULL)

Storage Maintenance Setup

Item

Factory default setting

Description

Check File System

Execute

Resolves any mismatch between actual memory and displayed memory available in a file system and performs administration data (FAT information) recovery.

Initial Lock

Enable

Sets whether to give permission to change settings associated with the memory initialization.

Language Maintenance Setup

Item

Factory default setting

Description

Select Language

English

Selects display language for the display screen.

Initialize*1

Execute

Deletes downloaded message files.

Job Cancel Setup

Item

Factory default setting

Description

Cancel Key Behavior

Short

Sets the behavior when the (CANCEL) button is pressed.

Short: Pressing the button for less than 2 seconds cancels the job.

Long: Pressing the button for 2 to 5 seconds cancels the job.

Off: Pressing the (CANCEL) button does not cancel the job.

Inquiry Display

On

Sets whether to display the confirmation screen when cancelling the job.

Focus Position

Yes

Sets an option between "Yes" and "No" to be highlighted on the confirmation screen displayed when cancelling the job.

Display Timeout

180

Sets timeouts for the confirmation screen of cancelling the job. When the confirmation screen timed out, printing is executed even the (CANCEL) button is pressed.

Admin Password

Item

Factory default setting

Description

New Password

Verify password

999999

Changes the administrator password.

Reset Settings*2

Item

Factory default setting

Description

Reset Settings*2

-

Deletes job macros and returns the settings to the default.

Save Settings

Item

Factory default setting

Description

Save Settings

-

Saves the current settings.

The most recently performed settings are saved and the previous ones are overwritten.

Restore Settings

Item

Factory default setting

Description

Restore Settings

-

Replaces the settings with the saved ones.

This item is displayed only when "Save Settings" is performed and the settings are saved.

Job Log Setup

Item

Factory default setting

Description

Clear Job Log*3

-

Clears the saved job logs.

Print Statistics

Item

Factory default setting

Description

Maintenance Counter

Disable

Sets whether to print the consumable counter's report.

Reset Main Counter

-

Resets the main counter.

Reset Supplies Counter

-

Reset the consumable counter.

This item is displayed when [Maintenance Counter] is set to [Enable].

  1. A message is displayed to confirm the equipment restarts automatically when changes have been made. Select [Yes] to continue. Select [No] to cancel.

  2. A message is displayed to confirm the equipment restarts automatically when executed. Select [Yes] to continue. Select [No] to cancel.

  3. A message is displayed to confirm that all job logs are deleted when executed. Select [Yes] to continue. Select [No] to cancel.