Operation Clear
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Operation Timeout |
3 |
Sets time for automatic reset of screen to begin. Available range: 1 to 10 minutes |
||
Clear After Job |
OFF |
Sets whether to reset after job is completed. |
Sound Control
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Paper Jam Error Buzzer Volume |
Middle |
Sets the volume for the paper jam alert tone. |
||
AirPrint Buzzer Volume |
Low |
Sets the AirPrint confirmation operation sound. |
Local Interface*1
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
USB Menu |
USB |
Enable |
Sets whether to enable USB. |
|
Soft Reset |
Disable |
Sets whether to enable the soft reset command. |
||
Speed |
480Mpbs |
Selects the maximum transfer speed of USB interface. |
||
Offline Receive |
Disable |
Set whether to receive data in offline state or in recoverable error state. |
||
Serial Number |
Enable |
Sets whether to use a USB serial number. |
||
Connected Host |
Normal |
Sets a host to be connected. |
System Setup
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Access Control |
Disable |
Sets access control. |
||
Default Authentication Method Setting |
Local Name |
Available only when [Access Control] is set to [Enable]. |
||
Unit of Measure |
Millimeter or Inch |
Selects a displayed unit (millimeter / inch). |
||
Default Paper Size |
A4 or Letter |
Sets the default paper size. |
||
Date Format |
dd/mm/yyyy or mm/dd/yyyy |
Sets the date format. |
||
Allow All Reports To Print |
Disable |
Sets whether to allow printing reports with personal information. |
||
Near Life LED |
Enable |
Sets whether to light an LED if a near life warning occurs. |
||
Near Life Status |
Enable |
Sets whether to display a message if a near life warning occurs. |
||
Status Display |
Toner Gauge |
Specify display information in idle Display. Paper Size: Display paper size of each tray. Toner Gauge: Display toner gauge. |
||
Panel Contrast |
0 |
Sets the contrast of the display screen. |
||
USB Memory Interface |
Enable |
If [Disable] is set, the print from USB Memory function cannot be used. |
Power Save
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Power Save Time |
1 minute |
Sets when to enter Power Save mode. |
||
Sleep Time |
15 minutes |
Sets when to enter Sleep mode. |
||
Auto Power Off Time |
4 hours |
Sets when to enter Auto Power Off. |
||
Silent Mode |
ON |
Specifies a print preparation operation when entering standby status from Sleep mode. If [ON] is set: it is quiet as there is no print preparation. If [OFF] is set: there is a rotation noise of the image to perform print preparation but you can start first printing early. |
||
ECO Mode*1 |
ON |
If [ON] is set: Printing starts even before the temperature of the fuser reaches the prescribed degrees, if the job is small. If [OFF] is set: Printing starts after the temperature of the fuser reaches the prescribed degrees. |
Memory Setup
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Receive Buffer Size |
Auto |
Sets the reception buffer size that local interface secures. |
||
Resource Save |
OFF |
Sets the resource save area. |
Flash Memory Setup*1
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Initialize |
Execute |
Initializes a flash memory. This item is displayed when [Initial Lock] is set to [Disable]. |
||
Format Partition |
PCL |
(NULL) |
Formats a partition. |
|
Common |
(NULL) |
|||
PS |
(NULL) |
Storage Maintenance Setup
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Check File System |
Execute |
Resolves any mismatch between actual memory and displayed memory available in a file system and performs administration data (FAT information) recovery. |
||
Initial Lock |
Enable |
Sets whether to give permission to change settings associated with the memory initialization. |
Language Maintenance Setup
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Select Language |
English |
Selects display language for the display screen. |
||
Initialize*1 |
Execute |
Deletes downloaded message files. |
Job Cancel Setup
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Cancel Key Behavior |
Short |
Sets the behavior when the Short: Pressing the button for less than 2 seconds cancels the job. Long: Pressing the button for 2 to 5 seconds cancels the job. Off: Pressing the |
||
Inquiry Display |
On |
Sets whether to display the confirmation screen when cancelling the job. |
||
Focus Position |
Yes |
Sets an option between "Yes" and "No" to be highlighted on the confirmation screen displayed when cancelling the job. |
||
Display Timeout |
180 |
Sets timeouts for the confirmation screen of cancelling the job. When the confirmation screen timed out, printing is executed even the |
Admin Password
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
New Password Verify password |
999999 |
Changes the administrator password. |
Reset Settings*2
Item |
Factory default setting |
Description |
|||
---|---|---|---|---|---|
Reset Settings*2 |
- |
Deletes job macros and returns the settings to the default. |
Save Settings
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Save Settings |
- |
Saves the current settings. The most recently performed settings are saved and the previous ones are overwritten. |
Restore Settings
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Restore Settings |
- |
Replaces the settings with the saved ones. This item is displayed only when "Save Settings" is performed and the settings are saved. |
Job Log Setup
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Clear Job Log*3 |
- |
Clears the saved job logs. |
Print Statistics
Item |
Factory default setting |
Description |
||
---|---|---|---|---|
Maintenance Counter |
Disable |
Sets whether to print the consumable counter's report. |
||
Reset Main Counter |
- |
Resets the main counter. |
||
Reset Supplies Counter |
- |
Reset the consumable counter. This item is displayed when [Maintenance Counter] is set to [Enable]. |
-
A message is displayed to confirm the equipment restarts automatically when changes have been made. Select [Yes] to continue. Select [No] to cancel.
-
A message is displayed to confirm the equipment restarts automatically when executed. Select [Yes] to continue. Select [No] to cancel.
-
A message is displayed to confirm that all job logs are deleted when executed. Select [Yes] to continue. Select [No] to cancel.