Default Mode
Item |
Factory default setting |
Description |
---|---|---|
Default Mode |
Home |
Sets the default mode screen of this machine. |
Operation Clear
Item |
Factory default setting |
Description |
---|---|---|
Operation Timeout |
3 |
Sets time for automatic reset of screen to begin. Available range: 1 to 10 minutes |
Clear After Job |
OFF |
Sets whether to reset after job is completed. |
Sound Control
Item |
Factory default setting |
Description |
---|---|---|
Key Touch Tone Volume |
Middle |
Sets the volume of the key-touch tone. |
JAM Buzzer Volume |
Middle |
Sets the volume for the paper jam alert tone. |
AirPrint Buzzer Volume |
Low |
Sets the AirPrint confirmation operation sound. |
Local Interface*1
Item |
Factory default setting |
Description |
|
---|---|---|---|
USB Menu |
Soft Reset |
Disable |
Sets whether to enable the soft reset command. |
Speed |
480Mpbs |
Selects the maximum transfer speed of USB interface. |
|
Offline Receive |
Disable |
Set whether to receive data in offline state or in recoverable error state. |
|
Serial Number |
Enable |
Sets whether to use a USB serial number. |
|
Connected Host |
Normal |
Sets a host to be connected. |
System Setup
Item |
Factory default setting |
Description |
---|---|---|
Access Control |
Disable |
Sets access control. |
Default Authent. Method Sett. |
Local Name |
Available only when [Access Control] is set to [Enable]. |
Unit of Measure |
Millimeter or Inch |
Selects a displayed unit (millimeter / inch). |
Default Paper Size |
A4 or Letter |
Sets the default paper size. |
Date Format |
dd/mm/yyyy or mm/dd/yyyy |
Sets the date format. |
Allow All Reports To Print |
Disable |
Sets whether to allow printing reports with personal information. |
Near Life LED |
Enable |
Sets whether to light an LED if a near life warning occurs. |
Status in Near Life |
Enable |
Sets whether to display a message if a near life warning occurs. |
USB Memory Interface |
Enable |
If [Disable] is set, the print from USB Memory function cannot be used. |
Panel Brightness During Operating |
7 |
Sets the LCD panel brightness. Available range: 1 to 7 (1 increments) |
Panel Brightness While Power Save |
0 |
Sets the LCD panel brightness. Available range: 0 to 7 (1 increments) |
Panel Calibration |
Execute |
Executes LCD panel calibration. |
Power Save
Item |
Factory default setting |
Description |
---|---|---|
Power Save Time |
1 minute |
Sets when to enter Power Save mode. |
Sleep Time |
15 minutes |
Sets when to enter Sleep mode. |
Auto Power Off Time |
4 hours |
Sets when to enter Auto Power Off. |
Silent Mode |
ON |
Specifies a print preparation operation when entering standby status from Sleep mode. If [ON] is set: it is quiet as there is no print preparation. If [OFF] is set: there is a rotation noise of the image to perform print preparation but you can start first printing early. |
ECO Mode*1 |
ON |
If [ON] is set: Printing starts even before the temperature of the fuser reaches the prescribed degrees, if the job is small. If [OFF] is set: Printing starts after the temperature of the fuser reaches the prescribed degrees. |
Memory Setup
Item |
Factory default setting |
Description |
---|---|---|
Receive Buffer Size |
Auto |
Sets the reception buffer size that local interface secures. |
Resource Save |
OFF |
Sets the resource save area. |
Flash Memory Setup*1
Item |
Factory default setting |
Description |
|
---|---|---|---|
Initialize |
Execute |
Initializes a flash memory. This item is displayed when [Initial Lock] is set to [Disable]. |
|
Format Partition |
PCL |
(NULL) |
Formats a partition. |
Common |
(NULL) |
||
PS |
(NULL) |
Storage Maintenance Setup
Item |
Factory default setting |
Description |
---|---|---|
Check File System |
Execute |
Resolves any mismatch between actual memory and displayed memory available in a file system and performs administration data (FAT information) recovery. |
Initial Lock |
Enable |
Sets whether to give permission to change settings associated with the memory initialization. |
Language Maint Setup
Item |
Factory default setting |
Description |
---|---|---|
Select Language |
English |
Selects display language for the LCD panel. |
Initialize*1 |
Execute |
Deletes downloaded message files. |
Keyboard Layout
Item |
Factory default setting |
Description |
---|---|---|
Keyboard Layout |
QWERTY |
Select which to use QWERTY keyboard or AZERTY keyboard for your keyboard on the touch panel. |
STOP Key Behavior
Item |
Factory default setting |
Description |
---|---|---|
STOP Key Behavior |
OFF |
Sets the behavior when the STOP key is pressed. Setting to ON cancels the print job. Setting to OFF disables the function. |
Admin Password
Item |
Factory default setting |
Description |
---|---|---|
New Password Enter password (Verify) |
999999 |
Changes the administrator password. 6 to 12 characters can be used. |
Reset Settings*2
Item |
Factory default setting |
Description |
---|---|---|
Reset Settings*2 |
- |
Deletes job macros and returns the settings to the default. |
Job Log Setup
Item |
Factory default setting |
Description |
---|---|---|
Clear Job Log*3 |
- |
Clears the saved job logs. |
Print Statistics
Item |
Factory default setting |
Description |
---|---|---|
Maintenance Counter |
Disable |
Sets whether to print the consumable counter's report. |
Reset Main Counter |
- |
Resets the main counter. |
Reset Supplies Counter |
- |
Reset the consumable counter. This item is displayed when [Maintenance Counter] is set to [Enable]. |
-
A message is displayed to confirm the equipment restarts automatically when changes have been made. Select [Yes] to continue. Select [No] to cancel.
-
A message is displayed to confirm the equipment restarts automatically when executed. Select [Yes] to continue. Select [No] to cancel.
-
A message is displayed to confirm that all job logs are deleted when executed. Select [Yes] to continue. Select [No] to cancel.