Manage Unit
Item |
Factory default setting |
Description |
|||
---|---|---|---|---|---|
Default Mode |
Home |
Sets the default mode screen of this machine. |
|||
Operation Clear |
Operation Timeout |
3 |
Sets time for automatic reset of screen to begin. Available range: 1 to 10 minutes |
||
Clear After Job |
OFF |
Sets whether to reset after job is completed. |
|||
Sound Control |
Key Touch Tone Volume |
Middle |
Sets the volume of the key-touch tone. |
||
Copy Buzzer Volume |
Middle |
Sets the volume for the copy complete sound. |
|||
FAX Buzzer Volume |
Middle |
Sets the volume for the transmission complete sound. |
|||
JAM Buzzer Volume |
Middle |
Sets the volume for the paper jam alert tone. |
|||
AirPrint Buzzer Volume |
Low |
Sets the AirPrint confirmation operation sound. |
|||
Local Interface*1 |
USB Menu |
USB |
Enable |
Sets whether to enable USB. |
|
Soft Reset |
Disable |
Sets whether to enable the soft reset command. |
|||
Speed |
480Mpbs |
Selects the maximum transfer speed of USB interface. |
|||
Offline Receive |
Disable |
Set whether to receive data in offline state or in recoverable error state. |
|||
Serial Number |
Enable |
Sets whether to use a USB serial number. |
|||
USB Assignment |
IPP |
Selects IPP-USB or Legacy for USB assignment. When scanning via USB, select Legacy. |
|||
System Setup |
Access Control |
Disable |
Sets access control. |
||
User Authentication Method |
Local |
Display condition: [Access Control] is set to [User] or [Password]. |
|||
Unit of Measure |
Millimeter or Inch |
Selects a displayed unit (millimeter / inch). |
|||
Default Paper Size |
A4 or Letter |
Sets the default paper size. |
|||
Date Format |
dd/mm/yyyy or mm/dd/yyyy |
Sets the date format. |
|||
Allow All Reports To Print |
Disable |
Sets whether to allow printing reports with personal information. |
|||
Near Life LED |
Enable |
Sets whether to light an LED if a near life warning occurs. |
|||
Status in Near Life |
Enable |
Sets whether to display a message if a near life warning occurs. |
|||
Address Information Lock Time Out |
30 minute(s) |
Sets time until a lock is released by the machine when an address book, telephone book, or profile is kept locked by the utilities. Available range: 1 to 60 minutes |
|||
USB Memory Interface |
Enable |
If [Disable] is set, the Scan To USB Memory and the print from USB Memory functions cannot be used. |
|||
Panel Brightness During Operating |
7 |
Sets the LCD panel brightness. Available range: 1 to 7 (1 increments) |
|||
Panel Brightness While Power Save |
0 |
Sets the LCD panel brightness. Available range: 0 to 7 (1 increments) |
|||
Panel Calibration |
Execute |
Executes LCD panel calibration. |
|||
Output Tray Paper Exist Lamp |
Enable |
Selects whether to flash LED when paper remains on the Upper Output Tray. Only for the models mounted the Upper Output Tray. |
|||
Power Save |
Power Save Time |
1 minute |
Sets when to enter Power Save mode. |
||
Sleep Time |
15 minutes |
Sets when to enter Sleep mode. |
|||
Auto Power Off Time |
4 hours |
Sets when to enter Auto Power Off. |
|||
Silent Mode |
ON |
Specifies a print preparation operation when entering standby status from Sleep mode. If [ON] is set: it is quiet as there is no print preparation. If [OFF] is set: there is a rotation noise of the image to perform print preparation but you can start first printing early. |
|||
ECO Mode*1 |
ON |
If [ON] is set: Printing starts even before the temperature of the fuser reaches the prescribed degrees, if the job is small. If [OFF] is set: Printing starts after the temperature of the fuser reaches the prescribed degrees. |
|||
Memory Setup |
Receive Buffer Size |
Auto |
Sets the reception buffer size that local interface secures. |
||
Resource Save |
OFF |
Sets the resource save area. |
|||
Flash Memory Setup*1 |
Initialize |
Execute |
Initializes a flash memory. Display condition: [Initial Lock] is set to [Disable]. |
||
HDD Setup*1 |
Initialize |
Execute |
Initializes a hard disk. Display condition: [Initial Lock] is set to [Disable]. |
||
Format Partition |
PCL |
(NULL) |
Formats a partition. |
||
Common |
(NULL) |
||||
PS |
(NULL) |
||||
Storage Maintenance Setup |
Check File System |
Execute |
Resolves any mismatch between actual memory and displayed memory available in a file system and performs administration data (FAT information) recovery. |
||
Check All Sectors |
Execute |
Performs recovery of a defective HDD sector information and a file system mismatch as mentioned above. |
|||
Erase HDD |
Execute |
This function erases all data on the hard disk. |
|||
Initial Lock |
Enable |
Sets whether to give permission to change settings associated with the memory initialization. |
|||
Encryption Setup |
Job Limitation |
Disable |
If [Encrypted Job only] is selected, all requests for print except encrypted authentication printing are ignored. If [ID Secure Job only] is selected, all printing jobs except for ID secured jobs are ignored. |
||
Language Maint Setup |
Select Language |
English |
Selects display language for the LCD panel. |
||
Initialize*1 |
Execute |
Deletes downloaded message files. |
|||
Admin Password |
New Password Enter password (Verify) |
aaaaaa |
Changes the administrator password. 6 to 12 characters can be used. |
||
Reset Settings*2 |
Execute |
Deletes job macros, fax transmission / reception data, and the history information, and returns the settings to the default. |
|||
Job Log Setup |
Clear Job Log*3 |
Execute |
Clears the saved job logs. |
||
Print Statistics |
Supplies Report |
Disable |
Sets whether to print the consumable counter's report. |
||
Reset Main Counter |
Execute |
Resets the main counter. |
|||
Reset Supplies Counter |
Execute |
Reset the consumable counter. Display condition: [Supplies Report] is set to [Active]. |
-
A message is displayed to confirm the equipment restarts automatically when changes have been made. Select [Yes] to continue. Select [No] to cancel.
-
A message is displayed to confirm the equipment restarts automatically when executed. Select [Yes] to continue. Select [No] to cancel.
-
A message is displayed to confirm that all job logs are deleted when executed. Select [Yes] to continue. Select [No] to cancel.